Table of Contents
The Advantages of ONAN Transformers
ONAN transformers, or Oil Natural Air Natural transformers, are renowned for their efficient cooling systems and high reliability. These transformers utilize natural oil circulation for cooling, which ensures that they operate at optimal temperatures even under heavy loads. This feature is particularly advantageous in industrial settings where the demand for electricity can fluctuate significantly.
In the context of a 1800 kVA transformer, the ONAN design enhances its performance by allowing for efficient dissipation of heat. This is critical because overheating can lead to transformer failure, resulting in costly downtimes. With ONAN technology, enterprises can expect a longer lifespan and lower maintenance costs, making it a smart investment.

Moreover, ONAN transformers are designed with robust materials that withstand extreme conditions, making them ideal for various applications. For Chinese enterprises, this translates to not only energy efficiency but also a high return on investment due to reduced operational costs over time.
High Cost Performance for Chinese Enterprises
When it comes to transformers, cost performance is a key consideration for businesses, particularly in China where competition is fierce. The 1800 kVA ONAN transformer stands out as a cost-effective solution without compromising on quality. Its design allows manufacturers to offer competitive pricing while ensuring reliability and efficiency.
| model | Rating power (KVA) | Voltage combination(KV) | Off-load losses(W) | Load losses(W) | Off-load current (%) | Short-circuit voltage (%) |
| SC13-30 | 30 | 6,6.3,6.6,10,11/0.4 | 150 | 710 | 2.3 | 4.0 |
| SC13-50 | 50 | 6,6.3,6.6,10,11/0.4 | 215 | 1000 | 2.2 | 4.0 |
| SC13-80 | 80 | 6,6.3,6.6,10,11/0.4 | 295 | 1380 | 1.7 | 4.0 |
| SC13-100 | 100 | 6,6.3,6.6,10,11/0.4 | 320 | 1570 | 1.7 | 4.0 |
| SC13-125 | 125 | 6,6.3,6.6,10,11/0.4 | 375 | 1850 | 1.5 | 4.0 |
| SCB13-160 | 160 | 6,6.3,6.6,10,11/0.4 | 430 | 2130 | 1.5 | 4.0 |
| SCB13-200 | 200 | 6,6.3,6.6,10,11/0.4 | 495 | 2530 | 1.3 | 4.0 |
| SCB13-250 | 250 | 6,6.3,6.6,10,11/0.4 | 575 | 2760 | 1.3 | 4.0 |
| SCB13-315 | 315 | 6,6.3,6.6,10,11/0.4 | 705 | 3470 | 1.1 | 4.0 |
| SCB13-400 | 400 | 6,6.3,6.6,10,11/0.4 | 785 | 3990 | 1.1 | 4.0 |
| SCB13-500 | 500 | 6,6.3,6.6,10,11/0.4 | 930 | 4880 | 1.1 | 4.0 |
| SCB13-630 | 630 | 6,6.3,6.6,10,11/0.4 | 1070 | 5880 | 0.9 | 4.0 |
| SCB13-630 | 630 | 6,6.3,6.6,10,11/0.4 | 1040 | 5960 | 0.9 | 6.0 |
| SCB13-800 | 800 | 6,6.3,6.6,10,11/0.4 | 1210 | 6960 | 0.9 | 6.0 |
| SCB13-1000 | 1000 | 6,6.3,6.6,10,11/0.4 | 1410 | 8130 | 0.9 | 6.0 |
| SCB13-1250 | 1250 | 6,6.3,6.6,10,11/0.4 | 1670 | 9690 | 0.9 | 6.0 |
| SCB13-1600 | 1600 | 6,6.3,6.6,10,11/0.4 | 1960 | 11700 | 0.9 | 6.0 |
| SCB13-2000 | 2000 | 6,6.3,6.6,10,11/0.4 | 2440 | 14400 | 0.7 | 6.0 |
| SCB13-2500 | 2500 | 6,6.3,6.6,10,11/0.4 | 2880 | 17100 | 0.7 | 6.0 |
This high cost performance is achieved through advanced manufacturing techniques that optimize the use of materials and energy. As a result, Chinese enterprises can benefit from lower initial costs and decreased energy consumption, which is crucial for maintaining profitability in today’s market.
Furthermore, the scalability of ONAN transformers means that they can be easily integrated into existing power systems. This flexibility allows companies to expand their electrical capacity without incurring significant additional expenses, making it an attractive option for future growth.
Conclusion on the Utility of ONAN Transformers
The utility of ONAN transformers, specifically the 1800 kVA model, cannot be overstated. These transformers offer a unique blend of performance, durability, and economic efficiency that meets the needs of modern Chinese enterprises. By investing in such technology, businesses can ensure they are well-equipped to handle the demands of a rapidly evolving energy landscape.

Moreover, the focus on high cost performance aligns perfectly with the goals of many companies looking to enhance their operational capabilities. The ability to achieve more with less is a hallmark of successful enterprises, and ONAN transformers play a pivotal role in this strategy.
| Type | Rated capacity (KVA) | Voltage combination(KV) | No-load losses(W) | Load losses(W) | No-load current (%) | Short-circuit voltage (%) |
| SZ11-2000 | 2000 | 33,35/6.3,6.6,10.5,11 | 2300 | 19240 | 0.80 | 6.5 |
| SZ11-2500 | 2500 | 33,35/6.3,6.6,10.5,11 | 2720 | 20640 | 0.80 | 6.5 |
| SZ11-3150 | 3150 | 33,35/6.3,6.6,10.5,11 | 3230 | 24710 | 0.72 | 7.0 |
| SZ11-4000 | 4000 | 33,35/6.3,6.6,10.5,11 | 3870 | 29160 | 0.72 | 7.0 |
| SZ11-5000 | 5000 | 33,35/6.3,6.6,10.5,11 | 4640 | 34200 | 0.68 | 7.0 |
| SZ11-6300 | 6300 | 33,35/6.3,6.6,10.5,11 | 5630 | 36800 | 0.68 | 7.5 |
| SZ11-8000 | 8000 | 33,35/6.3,6.6,10.5,11 | 7870 | 40600 | 0.60 | 7.5 |
| SZ11-10000 | 10000 | 33,35/6.3,6.6,10.5,11 | 9280 | 48100 | 0.60 | 7.5 |
| SZ11-12500 | 12500 | 33,35/6.3,6.6,10.5,11 | 10940 | 56900 | 0.56 | 8.0 |
| SZ11-16000 | 16000 | 33,35/6.3,6.6,10.5,11 | 13170 | 70300 | 0.54 | 8.0 |
| SZ11-20000 | 20000 | 33,35/6.3,6.6,10.5,11 | 15570 | 82800 | 0.54 | 8.0 |
Ultimately, the adoption of such advanced transformer technology signifies a commitment to sustainability and efficiency, essential factors in establishing a competitive edge in today’s global market. Whether for industrial applications or commercial use, ONAN transformers stand as a testament to innovation and reliability in energy solutions.